Good news!!! BMW ICOM A1, A2 Clone firmware has newly upgraded to current 1.40.05 1.25.02 in obdii365.com.
Current SYSTEM IMAGE version 01.25.02
Current APPLICATION IMAGE version 01.40.05
Note: 2015.11V BMW ICOM Rheingold ISTA-D ISTA-P version needs newest V1.40.05 firmware support.
Which specific version of BMW ICOM hardware to update firmware?
Perfect version ICOM A2: Item NO SP168-BA
BMW ICOM A1: SP101-B
Free download BMW ICOM A1/A2 firmware V1.40/1.25 bin files
How to update BMW ICOM A1,A2 firmware to V1.40/1.25?
Important Note:
To set your computer to automatically obtain IP address.
Steps
- Using LAN cable to connect ICOM A2/A1 with computer, using 12V power adapter or connecting ICOM device with BMW to supply power for ICOM A2/A1.
- Extract ICOM A1 A2 fw 1.40 upgrade files.
- Open IE Internet Explorer, for perfect version ICOM (SP168-BA, browse address
http://169.254.33.45:60080/, log in with username/password: root/NZY1150263;
For other version of ICOM A2 or A1 (NO SP168-C, SP168-B, SP168 and SP168-D), browse http://169.254.92.38:60080/, the login username and password are the same.
3. Click “Update Firmware“, you will see ICOM firmware version information.
- Click “Browse” to select file “ICOM-BootImage-01-24-00.bin“, set image type as “SYSTEM“, click “Send the file“.
- When “Write the image file to the flash?” pops up, click “Yes”, then ICOM indicator will turn red.
- When “The SYSTEM IMAGE update was successful” pops up, click “Update Firmware”.
- Choose “ICOM-ApplicationImage-01-38-01.bin“, set image type as “APPLICATION“, click “Send the file“, it will cost several minutes because the file is a little bit large.
- When “Write the image file to the flash?” pops up, click “Yes”, then the ICOM indicator will turn red for the second times.
- When upgrade complete, click “reboot“.
- Click “Home” – “Update Firmware” to check whether ICOM A2 firmware update to the newest version:
Current SYSTEM IMAGE version 01.25.02
Current APPLICATION IMAGE version 01.40.05
Note:
1. Setting up your computer to obtain an IP address automatically
2. Firstly choose the smaller file “ICOM-BootImage-01-13-00.bin” , then set image type to SYSTEM;
3. Secondly choose the bigger file “ICOM-ApplicationImage-01-18-00.bin”, then set image type to APPLICATION.